'BGM' AIR STERILISERS---a new concept of Air Sterilisation in OT / ICU / NICU / Doctor's Chamber / Burn-Ward / Maternity-Ward etc.
Kind attention: Doctors/Staffs in Hospitals & Nursing Homes, dedicated to the cause of reduction in post operative mortality, caused by Air born Infections.
Useful Information regarding ‘BGM Prion CID’ Air Sterilisers
Conventional and complicated sterilization techniques like fumigation are inefficient in handling sterility of air, which is the most important aspect. Most of the cross-infection occurs through air as all microorganisms travel through air borne particles. Fumigation technique has a very momentary effect as far as sterilization of air is concerned.
Other method as Laminar Air Flow System on the other hand is very bulky and requires large spaces. The running cost of these systems is very high. If not maintained properly such systems can cause havoc in the hospital premises.
We at Western India Electro-medical System Pvt. Ltd. believe in providing Reliable and Quality Products at a reasonable price. BGM Air Steriliser with the combination of electronic and mechanical filtration of air is the latest technique for providing safety, comfort and sterile air in Operation Theater and ICUs.
BGM Air Steriliser removes all the limitation and barriers of the existing system. It is particularly very helpful for Critical Care Centers, as this place cannot be sterilized using conventional techniques. ICUs are the most infectious place in the hospitals. Doctors and nurses are always at a threat of getting cross-infections in such places.
Another benefit of BGM Air Steriliser is that it provides 100% depreciation to its buyer. It comes under Pollution control equipments under the provision of Appendix I (See rule-5) to section 32 of Income Tax Act 1961.
The running cost of BGM Air Steriliser is very low as it consumes only 35 Watts of electricity. (Equal to a 40 Wt Tube light).
Overall BGM Air Steriliser is equipped with all the features that make it, a true winner for its buyer.
System function
BGM Air Steriliser should be mounted 5 feet above the ground level on a wall vertically. The lower grill should be focusing towards the operation Table. Positioning of BGM Air Steriliser should be the closest possible area near the operation region.
After switching on, BGM Air Steriliser start sucking in the air from the top perforated area at a speed of 160 CFM (Cubic Feet per Minute) and that air is processed through the 5 stage of filtration. Air that comes out thus, is free from all micro-organisms, particles and moisture. At the output of BGM Air Steriliser air is 100 % sterilized.
It can cover an area of 25,000 cubic feet (roughly 250 sq. feet) .One cycle of air takes 20 minutes. Ideally BGM Air Steriliser should be switched on 2 hours before the surgery for maximum result.
Working of each Filter:
1. Pre-Filter: It is a 5-micron filter to trap bigger size particles mainly dust. This filter stops dust particles from entering the machine.
2. E.S.P. or Electro Static Precipitator: This is the heart of BGM Air Steriliser. E.S.P. is made up of 7 pairs of plates (14 plates) one of which is held at a very high voltage and the other one are kept at zero volts. Thus a very heavy electro-static force is generated. When air passes through E.S.P. ----(1) The particles get charged and attracted towards the zero plate. They are precipitated there. (2) When micro-organism enter this region they are attracted on the zero plate and electrocuted with a very high voltage. (3) When CO2 (in air) come in this region, due to high electro-static force, carbon is split from oxygen and deposited on the zero plate and oxygen is released free, thus enriching the air with more Oxygen.
3. Ultra-Violet Tubes: There are two germicidal grade (2565 nanometer) Ultra Violet Tubes in BGM Air Steriliser. These U.V. Tubes kill all the microorganisms. It also ensures the inside of BGM Air Steriliser remains sterile all the time. U.V. radiation is completely sealed inside BGM Air Steriliser. No radiation comes out of the machine.
4. Activated Carbon-filter: In the first three filters, air is made completely sterile. Activated carbon is a very good absorbent of the moisture .It absorbs moisture reducing the amount of fungus. It also removes foul smell, bad-odor from the air, making a pleasant atmosphere.
5. HEPA or High Efficiency Particulate Arrestance Filter: This is a 0.3-micron filter .It is very efficient filter in trapping smallest of microorganisms. Generally there are no microorganisms smaller than 0.5-micron size.
BGM Air Steriliser thus ensures 100% sterilization of air. It also enriches air with oxygen and makes it pleasant by removing bad-odor from it.
Should you need further details, please feel free to contact us for any clarification and special offers etc.
Some of our popular PRODUCTS
BGM's Operation Theatre Air Steriliser
Present systems & their limitations in O.T. : |
|
|
Fumigation is carried out for killing the microbes and to avoid chances of infections during and after surgeries. It is basically a chemical process - a mist of fine atomized particles is sprayed in the operation theater. Since the microbes multiply rapidly in a short while, hence fumigation makes a momentary effect. Submicron size airborne particles are carriers of infection causing microbes, so lesser the number of submicron in airborne particles, lesser the number of microbes and ultimately even lesser the chances of operative infections. Generally fumigation is carried out 6 hours before any surgeries, But in case of emergencies and orthopedic surgeries, there is no time for prior air sterilization of the operation theater. In spite of it, surgeries are carried out in uncontrolled conditions, involving a lot of risk to the life of patients.
In our five stage O.T. Air Steriliser, Infection causing submicron size air-borne particles are trapped and electrocuted in the HEPA filter (0.3 m filtration) as well as in the electrostatic filters known as the E.S.P. and thus chances of infection are reduced to great extents. As BGM PRION-CID works round the clock, it cuts down the preparation time effectively as it brings the particle count to a dramatic minimal level.
 |
|
|
Specifications of our deferent models for Operation Theater Air Sterilisers:
|
|
|
|
MODEL |
BGM OT- I |
BGM OT-II |
BGM OT-III |
Height |
140mm |
150 mm |
150 mm |
Width |
400 mm |
400 mm |
660 mm |
Weight |
8 Kg aprox. |
9.8 Kg aprox. |
18 Kg aprox. |
Electrical |
240 Volts |
240 Volts |
240 Volts |
Power consumption |
30 Watts |
38 Watts |
70 Watts |
Air flow |
152 cubic mt./hr. |
203 cubic mt./hr. |
338 cubic mt./hr. |
Prefilter |
Non woven poly. |
Non woven poly. |
Non woven poly. |
A.C.Filter |
silver impregnated |
silver impregnated |
silver impregnated |
HEPA |
99.95% |
99.95% |
99.95% |
E.S.P. |
Germicidal type |
Germicidal type |
Germicidal type |
U.V.Lekage test |
florescent power certified |
florescent power certified |
florescent power certified |
U.V.Dose |
28,000 uw sec.per cm2 |
38,000 uw sec.per cm2 |
76,000 uw sec.per cm2 |
Microbiological test |
ISO 9001-2000 Lab. |
ISO 9001-2000 Lab. |
ISO 9001-2000 Lab. |
Area recommended |
43 cubic mt. |
79 cubic mt. |
127 cubic mt. |
Test method |
air sampling with petry plates |
air sampling with petry plates |
air sampling with petry plates |
|
|
BGM - OPD Air Steriliser
|
|
|

|
|
In the course of a day, a person inhales 15 cu. meter of air, hence the bacterial content of each breath is important, particularly when it contains high level pathogens. A doctor sitting in an O.P.D. for not less than 6 - 8 hours a day, is continuously exposed to this infectious atmosphere containing contagious pathogens.
Respiratory pathogens are directly transmitted through air during coughing, sneezing & talking, sending flying bacteria in to the air, Bacteria like hemolytic Streptococci and Staphylococcus, tubercle bacilli, diphtheria bacilli are the pathogens of major concern. |
BGM O.P.D Air sterilizer is designed after extensive research in microbiological air pollution for the last 10 years. The basic principal of BGM O.P.D is removing pollution and bacterial flora in your O.P.D. This will not only make you safe but also help in avoiding cross infections to the patients, today's latent need !
BGM O.P.D air steriliser is a multi stage air filtration system, with specially designed germicidal E.S.P the advance scientific technology to kill the bacteria in the air, along with removing bad odor, hazardous s.p.m, (Hazardous suspended particulate matter)etc. |
Technical Specifications
Height |
140 mm |
Width |
400 mm |
Weight |
8kg.appox |
Electrical |
220 Volts |
Power Consumption |
30 Watts |
C.F.M |
90 C.F.M |
dB rating |
37 db |
Prefilter |
Non woven poly |
A.C.Filter |
Silver impregnated |
HEPA Filter |
Efficiency 99.95% |
E.S.P |
Germicidal type |
U.V.Leakage test |
Fluorescent powder certified |
U.V Dose |
28,000W sec.per cm |
Microbiological tested by |
ISO 9001:2000 Lab |
Area recommended |
1500 cubic feet |
Test method |
Air flora sampling with settle plate count |
Q.M.S Certification |
(Q.C.B) ISO 9001: 2000 |
BGM- ICU Air Steriliser
|
|
|
In medically advance country like U.S.A., I.C.U. is a serious cause for nosocomial infections!
The Fatality Analysis Reporting Systems Organisation (FARSO) reported 37043 fatal crashes in 1999 in the US compared to estimate 88000 deaths in the 2 million patients who developed hospital acquired infections. As reported by CDC (Center for Disease Control) those admitted in intensive care unit are 5 to 10 times more likely to acquire nosocomial infections than other hospital patients. |
|

|
In India ICU, NICU, ICCU, is becoming prominent need of the society which enhance to provide emergency life saving. Basically patient admitted in ICU are in critical stage where any small nosocomial infection can cause nightmare for the doctor & patient. Basic limitation for maintaining sterility level in ICU are, like ICU cannot be fumigated very frequently and poisonous disinfectant cannot be used, another factor which makes this situation more serious i.e. visitors traffic in the ICU which is not controllable. As per world scientific studies for ICU, states that air in the ICU directly as well as indirectly plays major role in sterile environment to avoid critical infection conditions.
Worlds’ renowned medical research body like FARSO states that the deaths in hospital or nosocomial cause infection is 2.5 times than the road accident in countries like USA etc. We can imagine situation in Indian hospitals. The death ratio due to hospital caused infection is far more than other modernized countries, which being a very serious problem of all ICU's in India. In short ICU air sterilization is becoming a prominent need of every ICU in our country.
|
BGM ICU is specially designed for ICU environment. This high tech product capable to maintain air flora sterile at the rate of 300cu.ft./min. The basic principal is killing all types of micro organism in the air, and most important factor is it's safe equipment |
Technical Specifications
Length |
27" (690 mm) |
Height |
18" (465 mm) |
Depth |
6" (140 mm) |
Weight |
14kg (30.8 lbs) |
Electrical |
220 V - 50 Hz 80 Watt |
Area coverage |
250 sq. ft |
Air Flow |
300 C.F.M |
BGM's Dental Air Steriliser
Plasmacluster Ion Air Purification Technology is a heart of Bgm’s dental air steriliser and is based on using plasma to generate positive and negative ions surrounded by large numbers of water molecules that are then released in large quantities into the air. By taking advantage of the properties of ions to form cluster around micro particles (such as microbes and odor-causing molecules) and react chemically with them, airborne fungi (molds) are rendered inactive and odor-causing molecules are decomposed. WIESPL developed this technology in 2000, and has been deploying it in air cleaners, air conditioners, delivering new added value to the consumers. |
|

|
REQUIREMENT FOR DENTAL AIR STERILISER: People, through coughing, sneezing, and breathing, generate most of the bacteria's and viruses. However, a complex mixture of amoebas (one-cell animals), bacteria, molds, and fungi can breed in water reservoirs in humidifiers, air conditioners, and vaporizers. These appliances provide an ideal condition, not only for breeding, but also for dispensing the tiny microbes into the air you breathe.
Salient Features
- Equipped with Plasma cluster ion Air Purification Technology that generates Plasma cluster ions to knock out airborne viruses and mold fungi (all units)
- Plasma cluster ions are released from the air outlet of the unit, quickly eliminating airborne viruses and mold fungi that cause musty odors, effectively cleaning the air in an entire room.
- Small internal fan releases Plasma cluster ions in a 1.5-meter radius, cleaning the surrounding air. Fan control gives high airflow of 80 c.f.m. Quickly refreshing large rooms 1000 cu. ft. in approximately 30 minutes.
Running electricity costs of just 25 paisa / hour and low-noise operation.
- Uses additional activated carbon filter to clear odors (Cluster ions are molecular agglomerations ("clusters") consisting of positive and negative ions surrounded by water molecules. Cluster ions exist in abundance in nature, and are completely harmless to people.)
Model |
DAS-1000 |
Filters Dust collection
Odor removal |
Prefilter
Stamina Power Carbon
|
Airflow (C.F.M.) |
Max. 80 |
settings available |
airflow, ion |
External dimensions
(W x H x D) |
400 x145 x 400 mm |
Weight Approx. |
6.5 kg |
Max. Applicable area |
Approx. 1000 cubic feet |
Installation method |
Wall mounted |
Cluster ions are molecular agglomerations ("clusters") consisting of positive and negative ions surrounded by water molecules. Cluster ions exist in abundance in nature, and are completely harmless to people.
BGM's Opthalmic Air Steriliser
Plasmacluster Ion Air Purification Technology is a heart of Bgm’s Opthalmic air steriliser and is based on using plasma to generate positive and negative ions surrounded by large numbers of water molecules that are then released in large quantities into the air. By taking advantage of the properties of ions to form cluster around micro particles (such as microbes and odor-causing molecules) and react chemically with them, airborne fungi (molds) are rendered inactive and odor-causing molecules are decomposed. WIESPL developed this technology in 2000, and has been deploying it in air cleaners, air conditioners, delivering new added value to consumers. |
|

|
In the operation theater the sources of infection may be the either endogenous (from the patient himself) or exogenous (from the theatre environment). Airborne bacteria and viruses is frequently found in indoor air of any Ophthalmic clinic may represent a significant health risk. These micro organisms can carry infectious diseases such as influenza, Legionnaires, etc...
Most bacteria and viruses are generated by people, through coughing, sneezing, and breathing. However, a complex mixture of amoebas (one-cell animals), bacteria, molds, and fungi can breed in water reservoirs in humidifiers, air conditioners, and vaporizers. These appliances provide an ideal condition, not only for breeding, but also for dispensing the tiny microbes into the air you breathe.
PRINCIPALE OF BGM AIR STERILISER
It's a six-stage high-teak air-borne infection killer plant. Specially designed to suit the requirement of sterile air in Ophthalmic Operation Theater. It's the state-of-the-art is “P.e.f. (pulse electric field )” based electronic plazma inceration system which can kill even virus. This is world's latest technology used for killing airborne infections.
Salient Features
- Equipped with Plasma cluster Ion Air Purification Technology that generates Plasma cluster ions to knock out airborne viruses and mold fungi.
- Can be used in O.P.D. As well as In the O.T. Very effective method of air sterilisation.
- Electricity costs of just 40 paisa / hour and low-noise operation .
- Uses additional activated carbon filter to care odors
Cluster ions are molecular agglomerations (clusters) consisting of positive and negative ions surrounded by water molecules. Cluster ions exist in abundance in nature, and are completely harmless to people.
Model |
OPTH-1000 |
Filters Fine particles
Dust collection
Odor removal |
HEPA
Prefilter
Stamina Power Carbon |
Airflow (C.F.M.) |
Max. 80 |
settings available |
airflow, ion |
External dimensions
(W x H x D) |
360 x 999 x 342 mm |
Weight Approx. |
7.2 kg |
Max. Applicable area |
Approx. 1000 cubic feet |
Installation method |
Wall mounted |
|
|
Should you need further details, please feel free to contact us for any clarification and special offers etc.
|
Six stage bacteria killing plant built in air pollution remover with "PEF" based electronic plazma inceration chamber. Microbiologically certified by ISO 9001:2000 lab |
|
The contaminated air from the environment is taken in. Passes through different filters. Air-flow is of 120 cfm and washes the air inside the closed environment and drastically reduces the cfu count to a minimum level. |
BGM's Operation Theatre Air Steriliser
Present systems & their limitations : |
|
|
Fumigation is carried out for killing the microbes and to avoid chances of infections during and after surgeries. It is basically a chemical process - a mist of fine atomized particles is sprayed in the operation theater. Since the microbes multiply rapidly in a short while, hence fumigation makes a momentary effect. Submicron size airborne particles are carriers of infection causing microbes, so lesser the number of submicron in airborne particles, lesser the number of microbes and ultimately even lesser the chances of operative infections. Generally fumigation is carried out 6 hours before any surgeries, But in case of emergencies and orthopedic surgeries, there is no time for prior air sterilization of the operation theater. In spite of it, surgeries are carried out in uncontrolled conditions, involving a lot of risk to the life of patients. |
|

|
|
|
|
|
|
Infection causing submicron size air-borne particles are trapped and electrocuted in the HEPA filter ( 0.3 m filtration ) as weii as in the electrostatic filters known as the E.S.P. and thus chances of infection are reduced to great extents. As BGM PRION-CID works round the clock, it cuts down the preparation time effectively as it brings the particle count to a dramatic minimal level... |
MODEL |
BGM OT- I |
BGM OT-II |
BGM OT-III |
Height |
140mm |
150 mm |
150 mm |
Width |
400 mm |
400 mm |
660 mm |
Weight |
8 Kg appox. |
9.8 Kg appox. |
18 Kg appox. |
Electrical |
240 Volts |
240 Volts |
240 Volts |
Power consumption |
30 Watts |
38 Watts |
70 Watts |
Air flow |
152 cubic mt./hr. |
203 cubic mt./hr. |
338 cubic mt./hr. |
Prefilter |
Non woven poly. |
Non woven poly. |
Non woven poly. |
A.C.Filter |
silver impregnated |
silver impregnated |
silver impregnated |
HEPA |
99.95% |
99.95% |
99.95% |
E.S.P. |
Germicidal type |
Germicidal type |
Germicidal type |
U.V.Lekage test |
florescent power certified |
florescent power certified |
florescent power certified |
U.V.Dose |
28,000 uw sec.per cm2 |
38,000 uw sec.per cm2 |
76,000 uw sec.per cm2 |
Microbiological test |
ISO 9001-2000 Lab. |
ISO 9001-2000 Lab. |
ISO 9001-2000 Lab. |
Area recommended |
43 cubic mt. |
79 cubic mt. |
127 cubic mt. |
Test method |
air sampling with petry plates |
air sampling with petry plates |
air sampling with petry plates |
Some of our prestigious clients |
- A.F.M.C. (Armed forces medical college)
- Anand Hospital
- Ashwini Hospital
- Bansal Hospital
- Chugh Hospital
- Deodhar Nursinghome
- Dhanashree Hospital
- Dhanvantari Hospital
- Dindayal Memorial
- Dr. Jhamwar's Eye Hospital
- Ghandhi Nursinghome
- Kale Hospital
- Kamat Hospital
- Mahajan Hospital
|
- Mali Hospital (sagmner)
- Mokashi Hospital
- Muthiyan Eye Hospital
- NARI (National AIDS Research Institute)
- Natasha Eye Hospital
- National Hart Institute
- Pawar Hospital
- Phopale Nursing Home
- Puja Nursing Home
- Rakshak Hospital
- Shraddha Hospital
- Sudame Hospital
- Swaminathan Clinic
- Vishva Hospital
|
|
and many more hospitals....... |
|
Today's Hospital Problems & Limitations |
|
In advanced countries hospitals are highly equipped & patients are educated ,most importantly they expect best efforts from doctors. While in India the doctors are expected to do miracles ! On other side doctor's are facing many difficulties on many fronts. This in turn increases the psychological pressure on doctor. In addition, the consumer protection act, heavy competition, costly apparatus and high labor costs makes the matter more challenging! for the doctors. |
|
|

|
Your Profession And Sterile Air |
|
Your Nobel profession is to save patient's life. You have built your reputation by dedicated efforts for several years & there is always a pressure to maintain it. Today by international data, hospital acquired infection can create havocs for operative & post operative conditions. The sterile air (which is generally neglected) plays major role under infectious conditions in operation theater. This is unknown challenge to your reputation! |
|
|

|
How Much Do You Care Your Life? |
|
You are a person who is always exposed to Infectious Conditions .According to the Recent Scientific Studies Doctors and hospital staff needs to be protected from hospital Acquired infections. Today’s Polluted environment is another health Problem? |
|
|

|
How BGM Air Sterilize Works? |
|
The contaminated air from the environment is taken in. Passes through different filters and ESP. The air-outlet is 100 % sterile (certified by an ISO 9001: 2000 lab) Air-flow is of 120 cfm and washes Air-flow is of 120 cfm and washes and drastically reduces the cfu count to a minimum level. |
|
|

|
Principal of BGM steriliser Air |
|
It's a six-stage air-borne infection killer plant Especially designed to suit the requirement of STERILE-AIR in Operation Theater. It's the state-of-the-art PEF(Pulsed Electric Field) based ESP technology (as per EPA 68D 98118 – USA guidelines)
- Protects the doctor's and co-staff's life from Cross-infection.
- Reduces the Sox and Nox pollutants level.
- Reduces the effect of odors and irritating gases
- Protects the costly apparatus from fungus and dust.
- Maintains the microbial load even with traffic.
|

|
What's Infection? |
|
It's Bacterial contamination.
Sources of Infections
Endogenous - from patients
Exogenous - from theatre environment - equipment & articles
Prevention of Post-operative Infection |
|
- Effective Sterilization & disinfection techniques
- Good surgical techniques
- Proper Theater Design
- Restricting movement of Staff near the operating table
- Appropriate use of prophylactic antibiotics
|

|
Methods Applied to prevent exogenous infection |
|
- Fumigation
- Laminar Airflow System
- Change in Air
|

|
Existing Methods And Their Limitations (Fumigation) |
|
Very Old but effective in surface sterilization. Basically Formalin gas is used which is Carcinogenic. Fumigation does not maintain sterility of air for Long Time. Fumigation cannot take care of sterility of air during surgery science fume has to be drained out before surgery. |
|
|

|
Laminar Air Flow & Limitations |
|
The heart of Laminar Air Flow is HEPA filter.HEPA filters are designed to filter nuclear dust and NOT for medical application. The bacteria are collected and not killed. There is always fear of leakage. It has Very high Capital and Running costs. The Testing method is? Particle-count? and not? CFU-count? |
|
|

|
Pneumonia World's Number One Killer ! |
|
More than any other infectious disease, pneumonia remains the number one killer worldwide. Statistics for 1998 show that 3.5 million people died as a result of the disease. This alarming situation is due, in part, to widespread confusion over the difference between viral and bacterial respiratory infections. Recent studies undertaken by WHO indicate that for every 100 respiratory infections, only 20% require antibiotic treatment. This means that 80% of patients are treated with unnecessary medications thereby leading drugs directly into the sight lines of resistance. |
|
|

|
What is Fumigation? |
|
It's a chemical process which is effective in killing microbes present in air as well as on surfaces. Limitation are Since it's carcinogenic, it's not safe for the people in theater and also is can not control microbial air flora during surgery. |
Please let us know your interest and we will be glad to present our products and support our claims with evidences and offer you some important references about the reliability of our product.
Contact us at:
UPTECH INDIA
34, Bidhan Sarani (Near Vivekanand Road Crossing),
KOLKATA-700006 INDIA
Tele: 033-22413336 / 32964411 / 9339333337
Email: airsteriliser@gmail.com,
info@uptechindiaonline.com
URL: www.uptechindiaonline.com
DEALER NETWORK
- The company has established its sales & service network all over india.
- More than 1500 satisfied hospitals all over India.
The only company in air sterilisation which has received an ISO 9001: 2000 certification from QCB of Canada.
- The only company which has its own ISO 9001: 2000 laboratory.
More than a decades of Dedicated Efforts in Controlling Hospital Acquired Infections |
WIESPL has done Last Year turn over about One Crore & this Year heading for Multi Folds of this. Company has produced this range of product after more than10 Year's of dedicated efforts In this field. This concept has been honored with "Indira Ghandi Priyadarshani Award" in year 1997, presented by our late President of India, Shree Shankardayal Sharma.
An ISO 9001:2000 company of its own kind with the only in-house ISO 9001:2000 Certified Microbiological Research Laboratory. The Company is dedicated to doctors who strive to bring smiles to depressed hearts and hopes to the Tormented Souls. Western India Electro-medical Systems Pvt. Ltd. has started its commercial production in May 2001 at Chinchwad, Pune.
The company has a present manpower strength of 60 , which includes all India marketing & sales staff. WIEMS has set up its branches all over India through its distributor and dealer network. WIEMS's growth is almost 50 times over its last year financial performance. The company has a unit dedicated to microbiological research, development and testing. This has also been certified for ISO 9001: 2000 Quality Management Systems by Quality Certification Bureau of Canada. |
|
Products have also been tested and approved by recognized Microbiological test laboratories viz; |
|
Name of the Institute |
Place |
Govt Medical College |
Miraj |
YCM Hospital |
Pune |
Ashwini Sahakari Rugnlaya |
Solapur |
Central Drug Research Institute |
Lucknow |
Kolhapur Medical College |
Kolhapur |
Deendayal Hospital |
Pune |
|
|
WIEMS has products being successfully used in the domestic segment like Restaurants, Offices & Homes, also, wherein its utility is to combat the pollution related hazards within safety limits. The Company has established its sales & service network all over India. We have more than 1500 satisfied hospitals and nursing-homes as our clients, all over India. The only company in Air Sterilisation having received an ISO 9001:2000 Certification. The Only Company with its Own Microbiological ISO 9001: 2000 Laboratory. |
Should you need further details, please feel free to contact us for any clarification and special offers etc.
|